Lenovo 4219, 4220, 4222 Diagnostic Error Code, FRU/Action, XXX 014-014-XXX Parallel port Control

Models: 4221 4219 4215 4222 4220

1 178
Download 178 pages 48.44 Kb
Page 58
Image 58

Diagnostic Error Code

FRU/Action

 

 

 

011-196-XXXSerial port test halt, error threshold exceeded

1.

Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

011-197-XXXSerial port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

011-198-XXXSerial port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

011-199-XXXSerial port test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

 

011-2XX-XXXSerial port signal failure

1.

External serial device

 

2.

System board

 

 

014-000-XXXParallel port Interface Test Passed

No action

 

 

014-001-XXXParallel port Presence

1. Remove external parallel device, if present.

 

2.

Run the Setup Utility program, enable port

 

3.

System board

 

 

014-002-XXX014-003-XXXParallel port Timeout/Parity

System board

error

 

 

 

 

014-013-XXX 014-014-XXX Parallel port Control

System board

Signal/Loopback test failure

 

 

 

 

014-015-XXXParallel port External Loopback failure

1. Wrap plug

 

2.

System board

 

 

014-027-XXXParallel port Configuration/Setup error

1. Run the Setup Utility program, enable port

 

2.

Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

3.

System board

 

 

014-03X-XXX 014-04X-XXX Parallel port failure

System board

 

 

014-195-XXXParallel port Test aborted by user

Information only Restart the test, if necessary.

 

 

 

014-196-XXXParallel port test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

 

52Hardware Maintenance Manual

Page 58
Image 58
Lenovo 4219, 4220, 4222, 4215, 4221 manual Diagnostic Error Code, FRU/Action, XXX 014-014-XXX Parallel port Control