Diagnostic Error Code

FRU/Action

 

 

025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface

1. IDE signal cable

failure

2.

Check power supply.

 

 

3.

Reseat IDE signal cable.

 

4.

IDE device

 

5.

System board

 

 

025-195-XXXIDE interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

025-196-XXXIDE interface test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

025-197-XXXIDE interface test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

025-198-XXXIDE interface test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

025-199-XXXIDE interface test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

030-000-XXXSCSI interface Test Passed

No action

 

 

030-00X-XXX 030-01X-XXX SCSI interface failure

1. SCSI signal cable

 

2.

Check power supply

 

3.

SCSI device

 

4.

SCSI adapter card, if installed.

 

5.

System board

 

 

030-027-XXXSCSI interface Configuration/Setup error

1. SCSI signal cable

 

2.

Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

3.

SCSI device

 

4.

SCSI adapter card, if installed.

 

5.

System board

 

 

030-03X-XXX 030-04X-XXX SCSI interface error

1. SCSI signal cable

 

2.

Check power supply

 

3.

SCSI device

 

4.

SCSI adapter card, if installed.

 

5.

System board

 

 

030-195-XXXSCSI interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

56Hardware Maintenance Manual

Page 62
Image 62
Lenovo 4215, 4220, 4222, 4219 030-00X-XXX 030-01X-XXX Scsi interface failure, 030-03X-XXX 030-04X-XXX Scsi interface error