Lenovo 4215, 4220 Diagnostic error codes, Diagnostic Error Code, FRU/Action, XXX BIOS Timeout

Models: 4221 4219 4215 4222 4220

1 178
Download 178 pages 48.44 Kb
Page 52
Image 52
Diagnostic error codes

Diagnostic error codes

Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page 35 for the specific type for information about the diagnostic programs.

In the following index, X can represent any number.

Diagnostic Error Code

FRU/Action

 

 

000-000-XXXBIOS Test Passed

No action

 

 

000-002-XXX BIOS Timeout

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-024-XXXBIOS Addressing test failure

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-025-XXXBIOS Checksum Value error

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-026-XXXFLASH data error

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-027-XXXBIOS Configuration/Setup error

1. Run the Setup Utility program.

 

2.

Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

3.

System board

 

 

000-034-XXXBIOS Buffer Allocation failure

1. Reboot the system.

 

2.

Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

3.

Run memory test

 

4.

System board

 

 

000-035-XXXBIOS Reset Condition detected

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-036-XXXBIOS Register error

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-038-XXXBIOS Extension failure

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

Adapter card

 

3.

System board

 

 

000-039-XXXBIOS DMI data error

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

000-195-XXXBIOS Test aborted by user

Information only Restart the test, if necessary

 

 

000-196-XXXBIOS test halt, error threshold exceeded

1. Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

 

46Hardware Maintenance Manual

Page 52
Image 52
Lenovo 4215, 4220, 4222, 4219, 4221 manual Diagnostic error codes, Diagnostic Error Code, FRU/Action, XXX BIOS Timeout