Lenovo 4219, 4220, 4222, 4215 Diagnostic Error Code, FRU/Action, Press F3 to review the log file

Models: 4221 4219 4215 4222 4220

1 178
Download 178 pages 48.44 Kb
Page 63
Image 63

Diagnostic Error Code

FRU/Action

 

 

 

030-196-XXXSCSI interface test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

030-197-XXXSCSI interface test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

030-198-XXXSCSI interface test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

030-199-XXXSCSI interface test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

035-000-XXXRAID interface Test Passed

No action

 

 

035-0XX-XXXRAID interface Failure

1. RAID signal cable

 

2.

RAID device

 

3.

RAID adapter card, if installed

 

4.

System board

 

 

035-195-XXXRAID interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

035-196-XXXRAID interface test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

035-197-XXXRAID interface test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

035-198-XXXRAID interface test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

035-199-XXXRAID interface test failed, cause unknown

1. See “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

071-000-XXXAudio port Interface Test Passed

No action

 

 

 

Chapter 8. Symptom-to-FRU Index 57

Page 63
Image 63