Diagnostic error codes

Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page 50 for the specific type for information about the diagnostic programs.

In the following index, X can represent any number.

Diagnostic Error Code

FRU/Action

 

 

000-000-XXXBIOS Test Passed

No action

 

 

000-002-XXX BIOS Timeout

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-024-XXXBIOS Addressing test failure

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-025-XXXBIOS Checksum Value error

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-026-XXXFLASH data error

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-027-XXXBIOS Configuration/Setup error

1. Run the Setup Utility program.

 

2.

Flash the system. See “Flash update procedures”

 

 

on page 151.

 

3.

System board

 

 

000-034-XXXBIOS Buffer Allocation failure

1. Reboot the system.

 

2.

Flash the system. See “Flash update procedures”

 

 

on page 151.

 

3.

Run memory test

 

4.

System board

 

 

000-035-XXXBIOS Reset Condition detected

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-036-XXXBIOS Register error

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-038-XXXBIOS Extension failure

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

Adapter card

 

3.

System board

 

 

000-039-XXXBIOS DMI data error

1. Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

000-195-XXXBIOS Test aborted by user

Information only Restart the test, if necessary

 

 

000-196-XXXBIOS test halt, error threshold exceeded

1. Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

 

58ThinkCentre Edge Hardware Maintenance Manual