Diagnostic Error Code

FRU/Action

 

 

170-199-XXXVoltage Sensor(s) test failed, cause unknown

1. See “Undetermined problems” on page 78.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Replace component under function test.

 

 

170-250-XXX170-251-XXXVoltage Sensor(s) Voltage

1. Power supply

limit error

2.

System board

 

 

 

170-254-XXXVoltage Sensor(s) Voltage Regulator Module

1. Voltage Regulator Module (VRM)

error

2.

Microprocessor

 

 

3.

System board

 

 

175-000-XXXThermal Sensor(s) Test Passed

No action

 

 

175-0XX-XXXThermal Sensor(s) failure

1. Flash system

 

2.

System board

 

 

175-195-XXXThermal Sensor(s) Test aborted by user

Information only Restart the test, if necessary.

 

 

 

175-196-XXXThermal Sensor(s) test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

175-197-XXXThermal Sensor(s) test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

175-198-XXXThermal Sensor(s) test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled .

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Go to “Undetermined problems” on page 78.

 

 

175-199-XXXThermal Sensor(s) test failed, cause

1. See “Undetermined problems” on page 78.

unknown

2.

Flash the system and re-test. See “Flash update

 

 

 

procedures” on page 151.

 

3.

Replace component under function test.

 

 

175-250-XXX175-251-XXXThermal Sensor(s) limit error

1. Check fans

 

2.

Check power supply voltages.

 

3.

Microprocessor

 

4.

System board

 

 

185-000-XXXAsset Security Test Passed

No action

 

 

185-XXX-XXXAsset Security failure

1. Flash system

 

2.

System board

 

 

185-278-XXXAsset Security Chassis Intrusion

1. Assure Asset Security Enabled

 

2.

C2 Cover Switch

 

3.

System board

 

 

201-000-XXXSystem Memory Test Passed

No action

 

 

 

Chapter 7. Symptom-to-FRU Index 73

Page 79
Image 79
Lenovo 7558, 7567, 5068 manual XXXVoltage Sensors test failed, cause unknown