Diagnostic Error Code

FRU/Action

 

 

025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface

1. IDE signal cable

failure

2.

Check power supply.

 

 

3.

Reseat IDE signal cable.

 

4.

IDE device

 

5.

System board

 

 

025-195-XXXIDE interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

025-196-XXXIDE interface test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

025-197-XXXIDE interface test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

025-198-XXXIDE interface test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Go to “Undetermined problems” on page 78.

 

 

025-199-XXXIDE interface test failed, cause unknown

1. Go to “Undetermined problems” on page 78.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Replace component under function test.

 

 

030-000-XXXSCSI interface Test Passed

No action

 

 

030-00X-XXX 030-01X-XXX SCSI interface failure

1. SCSI signal cable

 

2.

Check power supply

 

3.

SCSI device

 

4.

SCSI adapter card, if installed.

 

5.

System board

 

 

030-027-XXXSCSI interface Configuration/Setup error

1. SCSI signal cable

 

2.

Flash the system. See “Flash update procedures”

 

 

on page 151.

 

3.

SCSI device

 

4.

SCSI adapter card, if installed.

 

5.

System board

 

 

030-03X-XXX 030-04X-XXX SCSI interface error

1. SCSI signal cable

 

2.

Check power supply

 

3.

SCSI device

 

4.

SCSI adapter card, if installed.

 

5.

System board

 

 

030-195-XXXSCSI interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

68ThinkCentre Edge Hardware Maintenance Manual

Page 74
Image 74
Lenovo 5068, 7567, 7558 manual 030-00X-XXX 030-01X-XXX Scsi interface failure, 030-03X-XXX 030-04X-XXX Scsi interface error