Diagnostic Error Code

FRU/Action

 

 

 

001-038-XXXSystem Extension failure

1.

Adapter card

 

2.

System board

 

 

 

001-039-XXXSystem DMI data structure error

1.

Flash the system. See “Flash update procedures”

 

 

on page 151.

 

2.

System board

 

 

 

001-040-XXXSystem IRQ failure

1.

Power-off/on system and re-test.

 

2.

System board

 

 

 

001-041-XXXSystem DMA failure

1.

Power-off/on system and re-test.

 

2.

System board

 

 

001-195-XXXSystem Test aborted by user

Information only Restart the test, if necessary

 

 

 

001-196-XXXSystem test halt, error threshold exceeded

1.

Press F3 to review the log file

 

2.

Restart the test to reset the log file

 

 

 

001-197-XXXSystem test warning

1.

Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

 

001-198-XXXSystem test aborted

1.

If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Flash the system and retest. See “Flash update

 

 

procedures” on page 151.

 

3.

Go to “Undetermined problems” on page 78.

 

 

 

001-199-XXXSystem test failed, cause unknown

1.

Go to “Undetermined problems” on page 78.

 

2.

Flash the system and re-test.

 

3.

Replace component under function test.

 

 

001-250-XXXSystem ECC error

System board

 

 

001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX

System board

System DMA error

 

 

 

 

001-260-XXX 001-264-XXX System IRQ error

System board

 

 

 

001-268-XXXSystem IRQ1 failure

1.

Device on IRQ1

 

2.

System board

 

 

 

001-269-XXXSystem IRQ2 failure

1.

Device on IRQ2

 

2.

System board

 

 

 

001-270-XXXSystem IRQ3 failure

1.

Device on IRQ3

 

2.

System board

 

 

 

001-271-XXXSystem IRQ4 failure

1.

Device on IRQ4

 

2.

System board

 

 

 

001-272-XXXSystem IRQ5 failure

1.

Device on IRQ5

 

2.

System board

 

 

 

60ThinkCentre Edge Hardware Maintenance Manual