Diagnostic Error Code

FRU/Action

 

 

201-XXX-XXXSystem Memory error

1. Replace the memory module called out by the test.

 

2.

System board

 

 

202-000-XXXSystem Cache Test Passed

No action

 

 

202-XXX-XXXSystem Cache error

1. Cache, if removable

 

2.

System board

 

3.

Microprocessor

 

 

206-000-XXXDiskette Drive Test Passed

No action

 

 

206-XXX-XXXDiskette Drive error

1. Diskette Drive Cable

 

2.

Check power supply voltages

 

3.

Diskette drive

 

4.

System board

 

 

215-000-XXXCD-ROM Drive Test Passed

No action

 

 

215-XXX-XXXCD-ROM Drive error

1. CD-ROM Drive Cable

 

2.

Check power supply voltages

 

3.

CD-ROM drive

 

4.

System board

 

 

217-000-XXXHard Disk Drive Test Passed

No action

 

 

217-25X-XXX217-26X-XXXHard Disk Drive (IDE) error

1. Hard Disk Drive Cable

 

2.

Check power supply voltages

 

3.

Reseat the hard disk drive cable

 

4.

Hard Disk drive (IDE)

 

5.

System board

 

 

217-28X-XXX217-29X-XXXHard Disk Drive (SCSI) error

1. Hard Disk Drive Cable

 

2.

Check power supply voltages

 

3.

Reseat the hard disk drive cable

 

4.

Hard Disk drive (SCSI)

 

5.

SCSI adapter card

 

6.

System board

 

 

220-000-XXXHi-Capacity Cartridge Drive Test Passed

No action

 

 

220-XXX-XXXHi-Capacity Cartridge Drive error

1. Remove the Hi-Capacity Cartridge Drive and re-test

 

 

the system.

 

 

301-XXX-XXXKeyboard error

1. Keyboard

 

2.

Check and test mouse.

 

3.

System board

 

 

301-000-XXXKeyboard Test Passed

No action

 

 

302-000-XXXMouse Test Passed

No action

 

 

302-XXX-XXX Mouse error

1. Mouse

 

2.

Check and test Keyboard.

 

3.

System board

 

 

303-000-XXXJoystick Test Passed

No action

 

 

303-XXX-XXXJoystick error

Remove the Joystick and re-test the system.

 

 

 

74ThinkCentre Edge Hardware Maintenance Manual

Page 80
Image 80
Lenovo 5068, 7567, 7558 manual XXX-XXX Mouse error