Diagnostic Error Code

FRU/Action

 

 

 

011-196-XXXSerial port test halt, error threshold exceeded

1.

Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

011-197-XXXSerial port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Re-run test

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

011-198-XXXSerial port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Go to “Undetermined problems” on page 78.

 

 

011-199-XXXSerial port test failed, cause unknown

1. Go to “Undetermined problems” on page 78.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Replace component under function test.

 

 

 

011-2XX-XXXSerial port signal failure

1.

External serial device

 

2.

System board

 

 

014-000-XXXParallel port Interface Test Passed

No action

 

 

014-001-XXXParallel port Presence

1. Remove external parallel device, if present.

 

2.

Run the Setup Utility program, enable port

 

3.

System board

 

 

014-002-XXX014-003-XXXParallel port Timeout/Parity

System board

error

 

 

 

 

014-013-XXX 014-014-XXX Parallel port Control

System board

Signal/Loopback test failure

 

 

 

 

014-015-XXXParallel port External Loopback failure

1. Wrap plug

 

2.

System board

 

 

014-027-XXXParallel port Configuration/Setup error

1. Run the Setup Utility program, enable port

 

2.

Flash the system. See “Flash update procedures”

 

 

on page 151.

 

3.

System board

 

 

014-03X-XXX 014-04X-XXX Parallel port failure

System board

 

 

014-195-XXXParallel port Test aborted by user

Information only Restart the test, if necessary.

 

 

 

014-196-XXXParallel port test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

 

64ThinkCentre Edge Hardware Maintenance Manual

Page 70
Image 70
Lenovo 7558, 7567, 5068 manual XXX 014-014-XXX Parallel port Control, 014-03X-XXX 014-04X-XXX Parallel port failure