Diagnostic Error Code

FRU/Action

 

 

071-00X-XXX 071-01X-XXX 071-02X-XXXAudio port error

1. Run the Setup Utility program.

 

2.

Flash the system. See “Flash update procedures”

 

 

on page 151.

 

3.

System board

 

 

071-03X-XXXAudio port failure

1. Speakers

 

2.

Microphone

 

3.

Audio card, if installed.

 

4.

System board

 

 

071-04X-XXXAudio port failure

1. Run the Setup Utility program.

 

2.

Audio card, if installed.

 

3.

System board

 

 

071-195-XXXAudio port Test aborted by user

Information only Restart the test, if necessary.

 

 

071-196-XXXAudio port test halt, error threshold exceeded

1. Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

071-197-XXXAudio port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

071-198-XXXAudio port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 53.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Go to “Undetermined problems” on page 78.

 

 

071-199-XXXAudio port test failed, cause unknown

1. See “Undetermined problems” on page 78.

 

2.

Flash the system and re-test. See “Flash update

 

 

procedures” on page 151.

 

3.

Replace component under function test.

 

 

071-25X-XXXAudio port failure

1. Speakers

 

2.

Audio card, if installed

 

3.

System board

 

 

080-000-XXXGame Port interface Test Passed

No action

 

 

080-XXX-XXXGame Port interface Error

1. Remove the game port device and re-test the

 

 

system.

 

 

080-195-XXXGame Port interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

080-196-XXXGame Port interface test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

 

70ThinkCentre Edge Hardware Maintenance Manual

Page 76
Image 76
Lenovo 7558, 7567, 5068 manual XXXAudio port test halt, error threshold exceeded