Diagnostic Error Code

FRU/Action

 

 

014-197-XXXParallel port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

014-198-XXXParallel port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

014-199-XXXParallel port test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

 

014-2XX-XXX 014-3XX-XXX Parallel port failure

1.

External parallel device

 

2.

System board

 

 

015-000-XXXUSB port Interface Test Passed

No action

 

 

015-001-XXXUSB port Presence

1. Remove USB device(s) and re-test.

 

2.

System board

 

 

015-002-XXXUSB port Timeout

1. Remove USB device(s) and re-test.

 

2.

System board

 

 

015-015-XXXUSB port External Loopback failure

1. Remove USB device(s) and re-test.

 

2.

System board

 

 

015-027-XXXUSB port Configuration/Setup error

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

System board

 

 

015-032-XXXUSB port Device Controller failure

System board

 

 

015-034-XXXUSB port buffer allocation failure

1. Reboot the system

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Run memory test.

 

4.

System board

 

 

015-035-XXXUSB port Reset condition detected

1. Remove USB device(s) and re-test.

 

2.

System board

 

 

015-036-XXXUSB port Register error

System board

 

 

015-040-XXXUSB port IRQ failure

1. Run the Setup Utility program and check for

 

 

conflicts.

 

2.

Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

3.

System board

 

 

015-195-XXXUSB port Test aborted by user

Information only Restart the test, if necessary.

 

 

 