Lexicon Improper, Configuring the MC-12for V4 EQ, The microphones SHOULD NOT be positioned

Models: MC-12

1 42
Download 42 pages 35.84 Kb
Page 28
Image 28
Manual background

Configuring the MC-12 for V4 EQ

Lexicon MC-12 Controller

IMPROPER

Figure 2-7. Improper microphone placement for automatic calibration.

Rear

Left

Side

Left

Rear

Right

Front

Left

Microphone

Side

 

Right

Center

Subwoofer

Front

Right

The microphones SHOULD NOT be positioned:

along the perimeter of the listening positions or listening area

in spots where listeners’ heads will not be during listening

in an obstructed line-of-sight path with the loudspeakers

in a location obstructed by furniture and other fixtures

within 2 feet (0.61m) of loudspeakers and walls

more than 30 feet (9.14m) from any one loudspeaker

The listening room to the left shows improper microphone placement for the automatic calibration. The microphones are positioned along the perimeter of the listening area, making it difficult for the MC-12 to calibrate optimal results for actual listening positions. In addition, the microphones are positioned in obstructed locations on the floor.

2-14

Page 28
Image 28
Lexicon Improper, Configuring the MC-12for V4 EQ, The microphones SHOULD NOT be positioned, Lexicon MC-12Controller