Image 23
Manual background

Version 4 EQ User Guide

Configuring the MC-12 for V4 EQ

The CHECK MICROPHONES results screen (shown to the right) opens on the on-screen display when the MC-12 finishes checking the microphones. This screen provides the results for each microphone. (The MC-12 refers to the microphones as 1, 2, 3, and 4 based on the microphone input connector to which the microphone is connected.)

CHECK MICROPHONES

MIC 1

ERROR

MIC 2

OK

MIC 3

OK

MIC 4

OK

PRESS V TO VIEW

DETAILS

PRESS X TO CONTINUE

Do not disconnect the microphones from the microphone input connectors. If the microphones are disconnected, perform the microphone check again before performing automatic calibration.

OK indicates that the microphone passed the microphone check.

ERROR indicates that the microphone did not pass the microphone check.

4. Press the

and

arrow buttons to highlight the desired

microphone.

 

 

5.Press the arrow button to view more detailed results for the selected microphone. The CHECK MICROPHONES Results table on the next page describes all possible results.

Once a successful microphone check has been performed:

The MC-12 retains the determined microphone level until the SPEAKER SETUP menu is closed. Once this menu is closed, another microphone check is required before automatic calibration can be performed.