Configuring the | Lexicon |
| Result | Description |
| Troubleshooting | ||
|
|
| The microphone detected calibration noise | N/A | ||
| (MICROPHONE) |
| ||||
|
| signals without error. |
|
|
| |
| OK |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The | • | Examine the microphone input connection to ensure that the microphone is properly connected | |
| (MICROPHONE) |
| ||||
|
| microphone during the silence check. |
| to the | ||
| NOT DETECTED |
|
| |||
|
|
|
| • | The microphone may be damaged. Contact an authorized Lexicon dealer for assistance. | |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| The microphone level determined during the | • | Examine the microphone input connection to ensure that the microphone is properly connected | |
| (MICROPHONE) |
| ||||
|
| silence check was not confirmed during the |
| to the | ||
| SIGNAL TOO LOW |
|
| |||
|
|
| microphone check. | • | The microphone may be positioned too far from the front loudspeakers. Refer to Positioning | |
|
|
| ||||
|
|
|
|
| the Microphones for the Microphone Check (page | |
|
|
|
|
| are properly positioned for the microphone check. | |
|
|
|
| • | The microphone may be damaged. Contact an authorized Lexicon dealer for assistance. | |
|
|
|
|
|
| |
|
|
| The microphone level is more than 20dB below | • | Examine the microphone input connection to ensure that the microphone is properly connected | |
| (MICROPHONE) |
| ||||
|
| the highest microphone level. |
| to the | ||
| OUT OF RANGE |
|
| |||
|
|
|
| • | The microphone may be positioned too far from the front loudspeakers. Refer to Positioning | |
|
|
|
| |||
|
|
|
|
| the Microphones for the Microphone Check (page | |
|
|
|
|
| are properly positioned for the microphone check. | |
|
|
|
| • | The microphone may be damaged. Contact an authorized Lexicon dealer for assistance. | |
|
|
|
|
|
| |
|
|
| The microphone level could not be determined | • | Eliminate extraneous noises in the listening room, including conversations, air conditioners, and | |
| (MICROPHONE) |
| ||||
|
| because of excessive noise in the listening |
| sounds that filter in through open doors and windows. | ||
| TOO MUCH ROOM NOISE |
|
| |||
|
|
| room. | • | The microphone may be damaged. Contact an authorized Lexicon dealer for assistance. | |
|
|
| ||||
|
|
|
|
|
|
|
REPOSITIONING THE MICROPHONES FOR AUTOMATIC CALIBRATION
Proper microphone placement is essential to achieve the desired automatic calibration results. Microphone placement determines whether the
For best results, automatic calibration should be performed with four microphones that have passed the microphone check. But, the