Lexicon manual Result, Troubleshooting, Configuring the MC-12for V4 EQ, Description

Models: MC-12

1 42
Download 42 pages 35.84 Kb
Page 24
Image 24
Result

Configuring the MC-12 for V4 EQ

Lexicon MC-12 Controller

 

Result

Description

 

Troubleshooting

 

 

 

The microphone detected calibration noise

N/A

 

(MICROPHONE)

 

 

 

signals without error.

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The MC-12 did not detect the

Examine the microphone input connection to ensure that the microphone is properly connected

 

(MICROPHONE)

 

 

 

microphone during the silence check.

 

to the MC-12. Make sure the microphone cable plug is fully inserted for a solid connection.

 

NOT DETECTED

 

 

 

 

 

 

The microphone may be damaged. Contact an authorized Lexicon dealer for assistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The microphone level determined during the

Examine the microphone input connection to ensure that the microphone is properly connected

 

(MICROPHONE)

 

 

 

silence check was not confirmed during the

 

to the MC-12. Make sure the microphone cable plug is fully inserted for a solid connection.

 

SIGNAL TOO LOW

 

 

 

 

 

microphone check.

The microphone may be positioned too far from the front loudspeakers. Refer to Positioning

 

 

 

 

 

 

 

 

the Microphones for the Microphone Check (page 2-6) to ensure that the microphones

 

 

 

 

 

are properly positioned for the microphone check.

 

 

 

 

The microphone may be damaged. Contact an authorized Lexicon dealer for assistance.

 

 

 

 

 

 

 

 

 

The microphone level is more than 20dB below

Examine the microphone input connection to ensure that the microphone is properly connected

 

(MICROPHONE)

 

 

 

the highest microphone level.

 

to the MC-12. Make sure the microphone cable plug is fully inserted for a solid connection.

 

OUT OF RANGE

 

 

 

 

 

 

The microphone may be positioned too far from the front loudspeakers. Refer to Positioning

 

 

 

 

 

 

 

 

 

the Microphones for the Microphone Check (page 2-6) to ensure that the microphones

 

 

 

 

 

are properly positioned for the microphone check.

 

 

 

 

The microphone may be damaged. Contact an authorized Lexicon dealer for assistance.

 

 

 

 

 

 

 

 

 

The microphone level could not be determined

Eliminate extraneous noises in the listening room, including conversations, air conditioners, and

 

(MICROPHONE)

 

 

 

because of excessive noise in the listening

 

sounds that filter in through open doors and windows.

 

TOO MUCH ROOM NOISE

 

 

 

 

 

room.

The microphone may be damaged. Contact an authorized Lexicon dealer for assistance.

 

 

 

 

 

 

 

 

 

 

REPOSITIONING THE MICROPHONES FOR AUTOMATIC CALIBRATION

Proper microphone placement is essential to achieve the desired automatic calibration results. Microphone placement determines whether the MC-12 calibrates optimal results for a single listening position; several listening positions in a single row; or several listening positions in the listening room.

For best results, automatic calibration should be performed with four microphones that have passed the microphone check. But, the MC-12 performs automatic calibration as long as at least one microphone has passed the microphone check. In this case, place the successfully checked microphone in the primary listening position.

2-10