4096-00X

Print Quality Service Check

 

FRU / Function

Action

 

 

 

1

Print Cartridge

Be sure the machine contains a good print

 

 

cartridge.

 

 

 

2

Color Print

Cross contamination of color inks results in

 

Cartridge Cross

incorrect colors printed, as when green prints for

 

Contamination

yellow, (when yellow and blue are mixed in the

 

 

print cartridge). This problem resolves quickly as

 

 

the print cartridge is used. If cross contamination

 

 

occurs, check:

 

 

• The maintenance station wiper for damage.

 

 

• The printhead nozzle plate was resealed with

 

 

 

tape.

 

 

 

3

Printhead Carrier

Reseat the printhead cables in the system board

 

Assembly

and check the following parts for wear or damage:

 

 

Print Cartridge Latch

 

 

Latch Spring

 

 

Carrier

 

 

 

 

2-12Service Manual