Lexmark 1000, 1100 manual 4096-00X, FRU / Function, Action, “Maintenance Station Service Check” on

Models: 1100 1000

1 56
Download 56 pages 3.38 Kb
Page 25
Image 25
“Maintenance Station Service Check” on

4096-00X

 

FRU / Function

Action

 

 

 

4

System Board

Execute the “Clean Print Nozzle” in “Cartridges” of

 

 

the Printer Control Program. Look for a break in

 

Printhead Cable

the diagonal line of the test pattern. A broken line

 

Rubber Backer

indicates one or more print nozzles are not

 

working. Run the test again to verify the failure. If

 

 

there are even breaks in the diagonal line similar to

 

 

the pattern shown below, ensure the printhead

 

 

cables are connected properly. If the symptom

 

 

remains, replace the system board.

 

 

If there is a single break or random breaks in the

 

 

diagonal line check the following:

 

 

• Check the gold-plated contacts, on the end of

 

 

the cable that connect to the carrier, for dirt and

 

 

wear. Use only a clean dry cloth to clean the

 

 

contacts. Also check the cable for damage. You

 

 

may need to remove the cable from the carrier

 

 

to inspect it.

 

 

• A worn rubber backer results in poor contact

 

 

between the printhead cable and the print

 

 

cartridge. Check the rubber backer for wear.

 

 

 

5

Maintenance

Intermittent nozzle failures can be caused by worn

 

Station

parts in the maintenance station. Perform the

 

 

“Maintenance Station Service Check” on

 

 

page 2-7, then return to this check.

 

 

 

6

Paper Feed

Ink smudging and smearing can be caused by

 

 

paper problems or problems in the paper feed

 

 

area.

 

 

Check the following:

 

 

• Correct type of paper is being used. Also check

 

 

the paper for curl or wrinkles.

 

 

• Feed rollers for wear, dirt, or looseness.

 

 

• Gears for wear or binds.

 

 

• Paper path for obstructions.

 

 

 

Diagnostic Information 2-13

Page 25
Image 25
Lexmark 1000, 1100 manual 4096-00X, FRU / Function, Action, “Maintenance Station Service Check” on