•use expansion bolts to fix the mounting supports on the wall
•use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level
•if the unit is installed on the wall or at the roof top, the supports have to be firmly fixed to resist earthquake or strong wind.
PIPELINES CONNECTION
Ordinary pipeline connection (suitable for
No dust, foreign objects, air or moisture should be allowed to enter the air conditioning system. Careful attention should be paid when the pipeline connection for the outdoor unit is made. Avoid (repeated) curves as much as possible, otherwise hardening or cracks might be caused to the pipes. Suitable wrenches should be used when the pipeline connection is done to ensure appropriate torque. Excessive torque might damage the joints while too little torque might lead to leakage.
For pipes vacuuming, see “Exhaust air” paragraph.
Torque wrench
Diameter of the copper pipe | Tightening torque |
|
|
|
|
|
|
|
|
| |
[“] / [mm] | [kgf*m] | [Lbs/feet] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Spanner | |||
1/4” / 6.35 mm | 1.6 | 11.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
3/8” / 9.52 mm | 3.0 | 21.7 |
| Nut of |
|
|
|
|
|
|
|
Joint |
|
| |||||||||
|
|
|
| connecti | ng pi | pe |
|
| |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
Connect the indoor connections (suitable for quick coupler)
Be aware that it is possible to connect the connectors only in one way. Follow the procedure below:
a. Remove the 4 dust caps from indoor connectors (unit and pipes).
b. Align the joint counter to the connecting pipe with the proper joint, tighten the connecting nuts manually. Then, make it secure with a wrench applying torque as shown in the table. If a torque meter is not available, secure the connector with 1 turn after manual secure.
c.Connect the drain hose to the indoor drain outlet. Wrap the drain tube with the refrigerant tubes tightly with tape. Make sure that the drain pipe is underneath the pipelines.
d.Connect the electric plugs, and place it above tubing in the back side of the unit.