INSTALLATION
See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances.
PAGE 11
RESIDENTIAL STANDARD
Using 6” (152 mm) Diameter Single Wall Con-
nector Pipe. Not Approved For Manufactured
(Mobile) Homes.
MANUFACTURED (MOBILE) HOME STANDARD
Using 6” (152 mm) Diameter Type L-Vent Connector Pipe
IMPORTANT NOTES:
Minimize the use of elbows (30°, 45° or 90°) - Offsets in the venting
system are very restrictive and will inhibit the draft (i.e. You will
lose approximately 5 feet of effective draft for every 90 degrees of
direction change). This appliance requires 12 to 15 feet of effective
draft for optimum performance (see Draft Requirements on
page 10).
First section of pipe must be vertical - Use as much straight verti-
cal pipe directly above the appliance as possible before using an
elbow (a 2’ to 3’ initial vertical rise is suggested).