CONTROLLING THE MULTIPLE PRODUCT 79

34. Natural Mode (Command: d j)

To assign the Tile Natural mode for Tiling function.

Transmission

[d][j][ ][Set ID][ ][Data][Cr]

Data

00 : Natural Off

01 : Natural On

ff : Read Status

Acknowledgement

[j][ ][Set ID][ ][OK/NG][Data][x]

37.Fan Fault check (Command: d w) To check the Fan fault of the Set.

Transmission

[d][w][ ][Set ID][ ][Data][Cr]

*The data is always FF (in Hex). Data

ff : Read Status

Acknowledgement

[w][ ][Set ID][ ][OK/NG][Data][x]

*Data is the status value of the Fan fault. Data

00 : Fan fault

01 : Fan Ok

02 : N/A (Not Avaliable)

ENGLISH

35. Picture Mode (Command: d x)

38. Elapsed time return (Command: d l)

To adjust the picture mode.

To read the elapsed time.

Transmission

[d][x][ ][Set ID][ ][Data][Cr] Data Structure

Data(Hex)

Mode

00

Vivid

01

Standard

 

 

02

Cinema

 

 

03

Sport

 

 

04

Game

 

 

Acknowledgement

[x][ ][Set ID][ ][OK/NG][Data][x]

36.Sound Mode (Command: d y) To adjust the Sound mode.

Transmission

[d][y][ ][Set ID][ ][Data][Cr] Data Structure

Data(Hex)

Mode

00

Standard

 

 

01

Music

 

 

02

Cinema

 

 

03

Sport

04

Game

 

 

Transmission

[d][l][ ][Set ID][ ][Data][Cr]

* The data is always FF(in Hex).

Acknowledgement

[l][ ][Set ID][ ][OK/NG][Data][x]

*The data is always FF(in Hex). (Hexadecimal code)

39.Temperature value (Command: d n) To read the inside temperature value.

Transmission

[d][n][ ][Set ID][ ][Data][Cr]

* The data is always FF(in Hex).

Acknowledgement

[n][ ][Set ID][ ][OK/NG][Data][x]

* The data is 1 byte long in Hexadecimal.

Acknowledgement

[y][ ][Set ID][ ][OK/NG][Data][x]

Page 79
Image 79
LG Electronics 47WS50MS, 42WS50MS owner manual DataHex Mode