LG Electronics 42WL10MS FAN Fault Check Command d w To check the fan errors, Key Command m c

Models: 42WL10MS 47WL10MS

1 83
Download 83 pages 61.97 Kb
Page 79
Image 79

78CONTROLLING THE MULTIPLE PRODUCT

ENGLISH

49.FAN Fault Check (Command: d w) To check the fan errors.

Transmission

[d][w][ ][Set ID][ ][Data][Cr] Data FF: Read the status

Acknowledgement

[w][ ][Set ID][ ][OK/NG][Data][x]

Data 00: Fan fault 01: Fan OK

02: Model without a Fan

50.Temperature Value (Command: d n) To check the inside temperature value.

Transmission

[d][n][ ][Set ID][ ][Data][Cr]

Data FF: Check the status Acknowledgement

[n][ ][Set ID][ ][OK/NG][Data][x]

* Temperature is displayed in hexadecimal.

51.Remote Controller Lock/ Key Lock (Command: k m)

When the remote control and front keys are locked in standby mode, the power cannot be turned on using the remote control or front power button.

Transmission

[k][m][ ][Set ID][ ][Data][Cr]

Data 00: Off (Lock Off)

01:On (Lock On)

* Display will not be turned on by power on key of remote controller and front panel control keys, if key is locked on in standby mode.

Acknowledgement

[m][ ][Set ID][ ][OK/NG][Data][x]

52.Key (Command: m c)

To send a key code of the IR remote control.

Transmission

[m][c][ ][Set ID][ ][Data][Cr] Data IR_KEY_CODE

Acknowledgement

[c][ ][Set ID][ ][OK/NG][Data][x] For a key code, see the IR Code.

*Some key codes are not supported depending on the model.

53.OSD Select (Command: k l)

To select OSD(On Screen Display) on/off.

Transmission

[k][l][ ][Set ID][ ][Data][Cr]

Data 00: Off

01:On

Acknowledgement

[l][ ][Set ID][ ][OK/NG][Data][x]

54.Elapsed time return (Command: d l) To check the panel used time.

Transmission

[d][l][ ][Set ID][ ][Data][Cr] Data FF: Read the status Acknowledgement

[l][ ][Set ID][ ][OK/NG][Data][x]

* Returned data means used hours in hexadecimal.