LG Electronics AMNC093APM0(LMAN090CNS) FunctionofIndoorUnit, Split Type Indoor Unit, Operation

Models: AMNC093APM0(LMAN090CNS) AMNH123DEA0 (LMN120HE) A2UC243FA0 (LMU240CE) AMNH123APM0(LMAN120HNS) A2UH243FA0(LMU240HE) AMNH093APM0(LMAN090HNS) AMNC123DEA0 (LMN120CE)

1 86
Download 86 pages 417 b
Page 45
Image 45
FunctionofIndoorUnit

Operation

Split Type Indoor UnitOperation ON/OFF by Remote controllerFunctionRoom temperature controlofStarting Current ControlIndoorTime Delay Safety ControlUnitIndoor Fan Speed ControlOperation indication Lamps (LED)Soft Dry Operation ModeSleep Mode Auto ControlNatural Air Control by CHAOS Logic* Airflow Direction ControlDeice (defrost) control (Heating)Hot-start Control (Heating)Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Split Type Indoor Unit

Operation ON/OFF by Remote controller

Sensing the Room Temperature

Room temperature sensor. (THERMISTOR)

Room temperature control

Maintains the room temperature in accordance with the Setting Temp.

Starting Current Control

Indoor fan is delayed for 5 seconds at the starting.

Time Delay Safety Control

Restarting is delayed for approx. 3 minutes.

Indoor Fan Speed Control

High, Med, Low, Chaos, Jet Cool

Operation indication Lamps (LED)

On/Off : Lights up during the system operation.

Sleep Mode : Lights up during Sleep Mode Auto operation.

Timer

: Lights up during Timer operation.

Defrost Mode : Lights up during Defrost Mode or Hot Start operation (Heat pump model only)

Outdoor unit : Lights up during outdoor unit operation.(Cooling model only) operation

Desire temperature For cooling,dehumidification,heating modes it display Destired temperature

indicator

• Cooling

: 18°C~30°C(64°F~86°F)

 

• AI

: Auto Operation

 

 

• Dehumidification

: 18°C~30°C(64°F~86°F)

 

• Po

: Jet Cool

 

• Heating

: 16~30°C(60°F~86°F)

 

• Lo

: Test Mode

Plasma : The function illustrates its dynamic mode by using a multiple lighting system. (Optional)

Soft Dry Operation Mode

Intermittent operation of fan at low speed.

Sleep Mode Auto Control

The fan is switched to low(Cooling), med(Heating) speed.

The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Natural Air Control by CHAOS Logic

The fan is switched to intermittent or irregular operation

The fan speed is automatically switched from high to low speed.

* Airflow Direction Control

The louver can be set at the desired position or swing up and down automatically.(Model base)

"Wall Mounted Type is standard"

* Functions is dependent on model type.

Deice (defrost) control (Heating)

Both the indoor and outdoor fan stops during deicing.

Hot start after deice ends.

Hot-start Control (Heating)

The indoor fan stops until the

evaporator piping temperature will be reached at 27°C(80.6°F).

Service Manual 45