LG Electronics A2UC243FA0 (LMU240CE) Connecting the Piping, Check, Indoor, For right rear piping

Models: AMNC093APM0(LMAN090CNS) AMNH123DEA0 (LMN120HE) A2UC243FA0 (LMU240CE) AMNH123APM0(LMAN120HNS) A2UH243FA0(LMU240HE) AMNH093APM0(LMAN090HNS) AMNC123DEA0 (LMN120CE)

1 86
Download 86 pages 417 b
Page 22
Image 22
Check

Flaring Work and Connection of Piping

Check

1.Compare the flared work with the figure by.

2.If a flared section is defective, cut it off and do flaring work again.

Smooth all round

 

 

Inside is shiny without scratches

 

= Improper flaring =

Inclined

Surface

Cracked Uneven

Even length

damaged

thickness

 

 

all round

 

 

Connecting the PipingConnecting the PipingIndoorFor right rear piping22Multi type Air ConditionerManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Indoor

1. Prepare the indoor unit's piping and drain hose for installation through the wall.

2. Remove the plastic tubing retainer(see the illustration by) and pull the tubing and drain hose away from chassis.

3. Replace only the plastic tubing holder 1, not the holder 2 in the original position.

For right rear piping

1.Route the indoor tubing and the drain hose in the direction of rear right.

2.Insert the connecting cable into the indoor unit from the out- door unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

3.Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the uper side can cause drain pan to overflow inside the unit.

If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweat- ing"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended.

Drain hose

Drain hose

Tape

 

Connecting

 

pipe

 

Drain hose

 

Connecting cable

Loop

Connecting

Gas side piping

 

cable

 

Drain hose

Liquid side piping

 

22Multi type Air Conditioner