PUMP

Pump Outlet Hose

Tub Pump

Bellows

HEATER

M6 heater nut

1Remove pump outlet hose.

2Remove tub pump bellows.

3Remove cap (Remaining Hose.)

4Disconnect the wiring.

5Unscrew 2 screws.

6Remove the pump.

Rating : 220~240V 50HZ 30W

Resistant : 160~177

1Loosen the M6 heater nut to pull out the heater.

CAUTION

When mounting the heater, be sure to insert the heater into the heater clip on the bottom of the tub.

Rating : 220~240V 2000W

Resistant : 24.7~28.0