Is the Standpipe Height greater than 1.0 m above the floor?

NO

When there is not water in the

YES

Observe Standpipe Height requirements of 1.0m maximum.

-Your washer will not be able to drain out water adequately, if the standpipe exceeds 1.0 m. In this case, water may flow back into the washer.

Check the Air Chamber and the Tube (clogged).

pump casing, is the water level frequency over 25.5KHz ?

YES

Is the Connector connected correctly to the Main PCB and the Pump Motor ? Or is the Harness alright ?

YES

Is the resistance of the Pump Motor out of 160 ~ 177?

Or is there the Impeller bind?

Bind

OR

NO And When you check the water level frequency again, if it is over 25.5KHz, you replace the Pressure switch.

NO

 

Reconnect or repair the Connector.

 

 

Or replace the Harness.

 

 

YES

Replace the Pump Motor.

NO

Is Pump motor started, when the spin

NO

 

Replace the Main PCB.

 

 

mode is started ?

 

 

 

24

Page 25
Image 25
LG Electronics F1256QD service manual Bind