7-4. ERROR DISPLAY
If you press the [Start/Pause] button when an error in displayed, any error except software ERROR will disappear and the machine will change into pause status.
In case of , , , if the error is not resolved within 15 sec. In case of other errors, if the error is not resolved within 4 min. Power will be turned off automatically and the error only will be
blinked. But in the case of , power will not be turned off.
| ERROR | SYMPTOM | CAUSE |
|
|
|
|
| |
1 | WATER INLET |
| Water has not reached to the | |
| since inlet valve operated, or water has not reached to | |||
ERROR |
| |||
|
| the normal level within 25 min. | Page 21 | |
|
|
| ||
|
|
|
|
|
|
|
| The appliance is tilted. |
|
2 | UNBALANCED |
| Laundry is gathered to one side. |
|
| ERROR |
| Non distributable things are put into the drum. | Page 22 |
|
|
| ||
|
|
|
|
|
3 | WATER OUTLET |
| Water has not drained enough within 8 min. | Page 23 |
ERROR |
| |||
|
|
|
| |
|
|
|
| |
4 | OVERFLOW |
| Water is automatically being pumped out because too | |
ERROR |
| amuch water is in the tub. | Page 25 | |
|
| |||
|
|
|
|
|
5 | PRESSURE SENSOR |
| The sensor pressure switch is out of order. | Page 26 |
S/W ERROR |
| |||
|
|
|
| |
|
|
|
| |
6 | DOOR OPEN |
| The [Start/Pause] button is pressed with the door open. | |
ERROR |
| The door switch is out of order. | Page 27 | |
|
| |||
|
|
|
|
|
7 | THERMISTOR(HEATING) |
| The thermistor is out of order. | Page 28 |
ERROR |
| |||
|
|
|
| |
|
|
|
|
|
|
|
| PWB ASSEMBLY (Main) is out of order |
|
8 | CURRENT |
| Replace the PWB assembly (Main) |
|
ERROR |
| Winding in the MOTOR is |
| |
|
|
| ||
|
|
| Replace the MOTOR |
|
|
|
|
| |
|
|
| The Connector | |
|
|
| is not connected to the Connector | |
|
|
| of MOTOR. |
|
| MOTOR |
| Reconnect or repair the connector |
|
|
| The electric contact between the connectors | ||
9 | LOCKED |
| male, white in the wire harness and | |
| ERROR |
| in the PWB ASSEMBLY (Main]) is bad or unstable. | |
|
|
| Reconnect or repair the contact in the connector | |
|
|
| The wire harness between the MOTOR and PWB | |
|
|
| ASSEMBLY (Main) is cut (open circuited). |
|
|
|
| The hall sensor is out of order/defective. | Page 29 |
|
|
|
|
|
10 | POWER |
| The washer experienced a power failure. |
|
FAILURE |
|
| ||
|
|
|
| |
|
|
|
|
|
20