3 Use spanner to remove transit bolts.
Without removal of transit bolts
Spin noise and shaking.
X 4 EA
Transit bolts
4 Confirm the distance between the appliance and the wall.
More than 2cm | If the distance is less than 2cm, | |
the water supply hose will | ||
| ||
| kink or fold. |
5 The tap connection and hose connection must be parallel.
1. Normal Tap without thread & screw type inlet hose.
1. Unscrew the fixing screw to | 2. Push the connector up till the |
attach the tap. | rubber packing is in tight contact |
| with the tap. Then tighten the 4 |
| screws. |
Upper | Rubber | |
packing | ||
Connector | ||
| ||
| Rubber packing | |
| Upper | |
| Connector | |
Fixing screw |
|
3.Push the water supply hose vertically upwards so that the rubber packing within in the hose can adhere completely to the tap and then tighten it by screwing it to the right.
Upper
Connector
Plate
Water supply hose
2. Normal Tap without thread & one touch type inlet hose (Single inlet models)
1.Untighten the upper connector screw.
Upper | Rubber |
Connector | packing |
Fixing screw
Middle connector
•In case the diameter of the tap is large remove the guide plate.
Guide plate
Connector
2.Push the upper connector up till the rubber packing is in tight contact with the tap. Then tighten the 4 screws.
Rubber packing
Upper
Connector
Middle connector
•Turn the middle connector not to have water leaked.
•Make sure that the rubber seal is inside the hose connector.
Hose connector
Rubber seal
3.Connect the water supply hose to the middle connector, pushing the plate down.
Upper
Connector Plate
Water supply
hose
•To separate the water supply hose from the middle connector shut off the tap.
Then pull the inlet hose down, pushing the plate down.
•Make sure that there are no kinks in the hose and that it is not crushed.
8