4-3. TEST MODE LDS4821 Series
CHECK PROGRAM
BUTTON | The number of | Top | Load and Checking points | Door open/ | ||
pushing button | Display | closed | ||||
|
| |||||
|
|
|
|
|
| |
RINSE+NORMAL | 1 TIME | n : 3H/U00 | All LEDs are lighting | Both | ||
+POWER S/W | ||||||
|
|
|
|
| ||
|
|
|
|
| ||
POWER SCRUB | 1 TIME | 1:11 | All LEDs are lighting | Both | ||
|
|
|
|
| ||
NORMAL | 1 TIME | 2:22 | All LEDs are lighting | Both | ||
|
|
|
|
| ||
QUICK | 1 TIME | 3:33 | All LEDs are lighting | Both | ||
|
|
|
|
| ||
RINSE ONLY | 1 TIME | 4:44 | All LEDs are lighting | Both | ||
|
|
|
|
|
| |
| 1 | TIME | Soil Level | Soil Sensor | Both | |
|
|
|
|
| ||
| 2 TIME | n:32 | Wash Pump | Closed | ||
|
|
|
|
|
| |
| 3 | TIME | n:33 | Drain Pump | Closed | |
|
|
|
|
|
| |
| 4 | TIME | ①Frequency | Inlet Valve | Both | |
|
|
|
|
|
| |
| 5 | TIME | n:35 | Dispenser | Closed | |
|
|
|
|
|
| |
RINSE | 6 | TIME | n:36 | Heater (for 10 sec) | Closed | |
|
|
|
|
| ||
7 | TIME | n:37 | Fan | Closed | ||
| ||||||
|
|
|
|
|
| |
| 8 | TIME | n:38 |
|
| |
|
|
|
|
|
| |
| 9 | TIME | Temp.(℃) | Thermistor | Both | |
| 10 | TIME | n:3a | Lower Nozzle(VARIO) | Closed | |
|
|
|
|
|
| |
| 11 | TIME | n:3b | Upper Nozzle(VARIO) | Closed | |
|
|
|
|
|
| |
| 12 | TIME | n:3c | Closed | ||
|
|
|
|
|
|
�Normal Water Level : 270
- 10 -