ELECTRICAL CONNECTIONS 7
ELECTRICAL CONNECTION REQUIREMENTS
This appliance must be installed and grounded on a branch circuit by a qualied technician in accordance with the National Electrical code ANSI/NFPA NO. 70 - latest edition.
All wiring should conform to Local and NEC. This range requires a
A range cord rated at 40 amps with 120/240 minimum volt range is required. If a 50 amp range cord is used, it should be marked for use with 13⁄8” diameter connection openings. This appliance may be connected by means of conduit or power cord. If conduit is being used, go to page 7 for 3 wire conduit connections or page 8 for 4
wire conduit connections.
WARNING
•New
•Power supply cord and plug should not be modied. If it will not t the outlet, have a
CONNECT RANGE CORD
The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block will then be accessible.
Terminal block
Power cord outlet
Cord/Conduit | Access |
connection | cover |
Drawer body plate |
|
FIgURE 4
The Cord/Conduit connection plate is used for the installation of power cord or conduit. For power cord, install it with the connection plate as INSTALLED. For conduit, remove the connection plate located below the rear of the drawer body and use the conduit hole (1 1/8”) instead of power cord hole (1 3/8”). (Refer to Figure 5 and 6.)
11/8"
(2.8cm)
|
|
| 13/8" |
|
| ||
13/8"(Cord) | 11/8"(Conduit) |
| (3.5cm) |
ENGLISH
•Using an extension cord to connect the power is prohibited. The way to connect the power cord and plug directly is strongly recommended.
•Electrical ground is required on this appliance.
•You should make sure that the power cord is not pinched by the range or heavy objects.
-Failure to do so can result in serious burns or electrical shock.
Range rating, watts |
| Diameter (inches) of Range | ||
|
| rating of power | connection Opening | |
120/240 volts | 120/208 volts | Power cord | Conduit | |
amperes |
|
| ||
8,750 - 16,500 7,801 - 12,500 | 40 or 50A | 1 3/8” | 1 1/8” | |
16,501 - 22,500 12,501 - 18,500 | 50 | 1 3/4” | 1 3/8” | |
| 3, 4 - Wire electrical wall Receptacle |
|
4 Wire receptacle (14-50R)
3 Wire receptacle
FIgURE 5
| Cord/conduit | |
| connection | |
Strain relief | plate | |
| ||
Conduit |
| |
Ring |
| |
| Conduit | |
Body | Assemble the | |
strain relief hole | ||
|
Cord Strain relief
Reinstall the Cord/Conduit connection plateFIgURE 3 | FIgURE 6 |
|