4-WIRE CONNECTION WITH A POWER SUPPLY CORD

ELECTRICAL CONNECTIONS 9

4-WIRE CONNECTION WITH A POWER SUPPLY CORD

3-WIRE CONNECTION: CONDUIT WARNING

Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed-loop connectors or open-end spade lugs with upturned ends shall be used. The middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire must be connected to the frame of the range with the ground screw.

-Failure to do so can result in electrical shock, severe personal injury or death.

Install the power cord as follows:

For power cord installations, Hook the strain relief over the power cord hole (13/8”) located below the rear of lower oven. Insert the power cord through the strain relief and tighten it. (Refer to Figure 7.)

DO NOT install the power cord without a strain relief.

1.Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 9.)

2.Remove ground strap and discard as show in in Figure 9.

3.Insert the ground screw into the power cord ground wire terminal ring and secure it to the range frame.

4.Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block. Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block.

5.Tighten 3 screws securely into the terminal block.

3-WIRE CONNECTION: CONDUIT

Install the conduit as follows:

Remove the Conduit connection plate from the rear of lower oven and rotate it as shown in Figure 5. The conduit hole (11/8") must be used.

First, prepare the conduit wires as shown in Figure 10.

3 wire

4 wire

Conduit

Ground

connection

strap

plate

 

3 wire

or

 

FIgURE 10

Second, install conduit as shown in Figure 6.

For conduit installations, after purchasing a strain relief, insert it in the conduit hole (11/8”). Then install the conduit through the body of strain relief and fasten the strain relief with its ring. Reinstall the bracket.

For conduit connections :

If the wire in the conduit is copper it must be 8 or 10 AWG wiring.

If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring.

1.Loosen the lower 3 screws from the terminal block. Refer to Figure 11.)

2.Insert the bare wire (white/neutral) end through the center terminal block opening. Do not remove ground strap connections.

3.Insert the two side bare wire ends into the lower left and the lower right terminal block opening. Tighten the 3 screws securely into the terminal block . (approximately 35 - 50 IN-LB)

4.Refer to page 11.

ENGLISH

4-wire connection

3-wire connection

Black

White Red

Black White Red

 

Terminal

Terminal

 

block

 

block

 

 

 

Ground

 

 

strap

 

 

Remove ground

Wire ends

 

 

 

strap and discard

 

 

 

Conduit

Ground screw

Conduit

connection plate

 

connection plate

 

FIgURE 9