LG Electronics LRE3025SB Installation Drawings, Cautioncaution, Prepare To Install The Range

Models: LRE3025ST LRE3023SW LRE3023ST LRE3023SB LRE3025SW LRE3025SB

1 13
Download 13 pages 5.48 Kb
Page 6
Image 6
6PREPARE TO INSTALL THE RANGE

6PREPARE TO INSTALL THE RANGE

INSTALLATION DRAWINGS

INSTALLATION DRAWINGS NOTE

SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR

CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1.

For installation in CANADA, a Free-standing range is not to be installed closer than 15/32 (12mm) from any adjacent surface.

CAUTIONCAUTIONCAUTIONManual backgroundCAUTION

Make sure that the wall covering, countertop and cabinets around the range can with- stand the heat (up to 194°F) generated by the range.

-Discoloration, delamination or melting may occur.

-This range has been designed to comply with the maximum allowable wood cabinet tem- peratures of 194°F.

A = 30 (76.2 cm) For U.S.A

=30 (76.2 cm) ~ 31 (78.7 cm) For CANADA

FIgURE 1

MINIMUM DIMENSIONS (Figure 2)

Cabinet storage space located above the surface units should be avoided.

Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets if cabinet storage is to be provided.

- Manual background heated surface elements can be reduced.

FIgURE 2

*30" (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24" (60.9 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4”(6.4 cm) ￿ame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" (0.381 mm) stainless steel, 0.024" (0.610 mm) aluminum or 0.020" (0.508 mm) copper.

**15" (38.1 cm) minimum between countertop and adjacent cabinet bottom.

Page 6