8ELECTRICAL CONNECTIONS
3-WIRE CONNECTION WITH A POWER SUPPLY CORD
WARNING
•The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block.
-Failure to do so can result in electrical shock, severe personal injury or death.
Install the power cord as follows:
For power cord installations, Hook the strain relief over the power cord hole (13/8”) located below the rear of lower oven. Insert the power cord through the strain relief and tighten it. (Refer to Figure 7.)
DO NOT install the power cord without a strain relief.
1.Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 8.)
2.Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block. Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block.
3.Tighten 3 screws securely into the terminal block. Do not remove the ground strap connections.
4.Refer to page 11.
Cord strain relief |
|
| Conduit |
| connection |
| plate |
Separate Strain Relief |
|
before installation |
|
Assemble the strain relief | Power cord |
to the 1 3/8” opening in |
|
Conduit connection plate |
|
FIgURE 7
3-wire connection
Black White Red
Terminal block
Conduit connection plate
FIgURE 8