11. TEST AND CHECKOUT PROCEDURES, AND TROUBLESHOOTING

11. TEST AND CHECKOUT PROCEDURES, AND TROUBLESHOOTING

CAUTIONS

1.DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH VOLTAGE CAPACITOR AND REMOVING THE LEAD WIRES FROM THE INVERTER MODULE.

2.ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER OF WATER IN CONTAINER) IN THE OVEN.

A.TEST PROCEDURES

COMPONENTS

TEST PROCEDURE

RESULTS

INVERTER

(Lead wires removed)

CN702

Heat Sink

E701

120V AC

CN701

High Voltage

 

Output to

 

Magnetron

 

CN703

 

Control Signal

 

In/Out

Note: Do not try to repair the inverter board, nor try to make any adjustments to the board.

Check wiring to the inverter:

1.Unplug the oven’s main power supply.

2.Visually inspect 4 connectors on the inverter board: CN701, CN702, CN703, E701 to see whether there are any signs of failure due to loose wires, bad crimping, sign of overheating, etc.

MAGNETRON

1. Measure the resistance.

 

(Lead wires removed)

Normal: Less than 1 ohm

(Ohm-meter scale: Rx1)

 

 

 

 

• Filament terminal

 

 

2. Measure the resistance.

Normal: Infinite

 

(Ohm-meter scale: Rx1000)

 

 

 

• Filament to chassis

 