B.CHECKOUT PROCEDURES

(1)CHECKOUT PROCEDURES FOR FUSE BLOWING

CAUTION: REPLACE BLOWN FUSE WITH 20 AMPERE FUSE.

PROBLEMS

 

CAUSES

 

 

 

 

Fuse blows immediately after

 

 

 

 

Improper operation of the primary interlock,

 

the door is closed.

 

 

 

 

secondary interlock switches and/or the interlock

 

 

 

 

Fuse blows immediately after

 

monitor switch.

 

the door is opened.

 

 

 

 

 

 

 

Fuse blows when the door is closed and START key

 

Malfunction of the Inverter, the magnetron,

 

is touched.

 

the fan motor or the circuit board.

 

 

 

 

 

 

 

 

 

NOTES:

-If the fuse is blown by an improper switch operation, replace the defective switches and the fuse at the same time. After replacing the defective switches with new ones, make sure that they are correctly connected.

-Check for microwave energy leakage according to “1. ADJUSTMENT PROCEDURES” on page 3, when the primary interlock, secondary interlock switches and/or the interlock monitor switches are adjusted or replaced.