LG Electronics LS305HV installation manual Wiring Diagram, Outdoor unit

Models: LS305HV

1 31
Download 31 pages 342 b
Page 22
Image 22
Wiring Diagram

Installation

Outdoor

1.Remove the cover control from the unit by loosening the screw.

Connect the wires to the terminals on the control board individually as the following.

2.Secure the cable onto the control board with the holder (clamper).

3.Refix the cover control to the original position with the screw.

Wiring Diagram

Outdoor unit

 

Terminal block

 

Over 5mm

 

(0.2")

Conduit panel

Power supply

 

cord

Connecting

 

 

cable

Cover control

 

NOTICE

1.Separately wire power supply cord and connecting cable.

2.Use heat-proof electrical wiring capable of withstanding temperature up to 75°C(167°F).

3.Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and outdoor unit. (For example, Type SJO-WA)

Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and wiring method, etc).

Every wire must be connected firmly.

No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.