| Installation |
Check |
|
|
|
1. Compare the flared work with the figure by. | Smooth all round |
|
|
2. If a flared section is defective, cut it off and | Inside is shiny without scratches | ||
|
|
| |
do flaring work again. |
| = Improper flaring = | |
|
| ||
| Inclined | Surface | Cracked Uneven |
| Even length | damaged | thickness |
|
|
| |
| all round |
|
|
ConnectingthePiping
Indoor
1. Prepare the indoor unit's piping and drain hose for installation through the wall.
2. Remove the plastic tubing retainer(see the illustration by) and pull the tubing and drain hose away from chassis.
3. Replace only the plastic tubing holder 1, not the holder 2 in the original position.
ENGLISH
For right rear piping |
|
| |
1. Route the indoor tubing and the drain hose in |
|
| |
the direction of rear right. |
|
| |
2. Insert the connecting cable into the indoor unit |
|
| |
from the outdoor unit through the piping hole. | Drain hose | ||
• Do not connect the cable to the indoor unit. | |||
|
| ||
• Make a small loop with the cable for easy |
|
| |
connection later. |
|
| |
3. Tape the tubing, drain hose, and the |
|
| |
connecting cable. Be sure that the drain hose |
|
| |
is located at the lowest side of the bundle. |
|
| |
Locating at the uper side can cause drain pan |
|
| |
to overflow inside the unit. |
|
| |
If the drain hose is routed inside the room, |
|
| |
insulate the hose with an insulation material* | Tape |
| |
so that dripping from "sweating"(condensation) | Connecting |
| |
will not damage furniture or floors. | pipe |
| |
|
| ||
*Foamed polyethylene or equivalent is | Drain hose |
| |
recommended. | Connecting cable |
| |
| Installation Manual | 15 |