LG Electronics M4710C manual Temperature value Command d n, Lamp fault CheckCommand d p

Models: M4710C

1 54
Download 54 pages 7.54 Kb
Page 52
Image 52

RS-232CControlling the Multiple Product

Transmission / Receiving Protocol

26.Temperature value (Command : d n)

To read the inside temperature value.

Transmission

[d][n][][Set ID][][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[n][][Set ID][][OK/NG][Data][x]

* The data is 1 byte long in Hexadecimal.

27. Lamp fault Check(Command : d p)

To check lamp fault.

Transmission

[d][p][][Set ID][][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[p][][Set ID][][OK/NG][Data][x]

Data 0 : Lamp Fault

1: Lamp OK

A16

Page 52
Image 52
LG Electronics M4710C manual Temperature value Command d n, Lamp fault CheckCommand d p