Application Guidelines/Water Supply Parameters | Caution | ||
|
| To reduce the risk associated with property | |
Service Flow | 0.5 gpm (1.9 lpm) | ||
damage due to water leakage: | |||
Water Supply | Potable Water | yy Read and follow. Use Instructions before | |
|
| installation and use of this system. | |
Water Pressure | 20 | ||
yy Installation and use MUST comply with all | |||
|
| ||
Water Temperature | 33°F - 100°F (0.6°C - 38°C) | state and local plumbing codes. | |
yy Do not install if water pressure exceeds | |||
|
| ||
|
| ||
It is essential that the manufacturer’s | 120 psi (827 kPa). If your water pressure | ||
recommended installation, maintenance and | exceeds 80 psi, you must install a | ||
filter replacement requirements be carried out | pressure limiting valve. Contact a plumbing |
for the product to perform as advertised. | professional if you are uncertain how to | |
check your water pressure. | ||
|
NOTE
yy While the testing was performed under standard laboratory conditions, actual performance may vary.
Replacement Cartridge: ADQ36006101
For estimated costs of replacement elements please call USA
CANADA
3M is a trademark of 3M Company. NSF is a trademark of NSF International. © 2009 3M Company. All rights reserved.
Warning
To reduce the risk associated with choking:
yy Do not allow children under 3 years of age
to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
yy Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. EPA Establishment #
yy Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you uncertain how to check for this condition.
yy Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C).
yy Protect filter from freezing. Drain filter when temperatures drop below 40°F (4.4°C).
yy The disposable filter cartridge MUST be replaced every 6 months, at the rated capacity or if a noticeable reduction in flow rate occurs.
yy Protect from freezing, remove filter cartridge when temperatures are expected to drop below 33° F.
yy Do not install systems in areas where ambient temperatures may go above 110° F (43.3° C).
yy Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.
yy Ensure all tubing and fittings are secure and free of leaks.
Manufactured for LG®Electronics by CUNO Incorporated 400 Research Parkway Meriden, CT 06450 U.S.A Worldwide: