LG Electronics P154 Flow Check Duct Condition Test, To activate the flow check Duct condition test

Models: P154

1 132
Download 132 pages 24.73 Kb
Page 24
Image 24
 FLOW CHECK (DUCT CONDITION TEST)

To activate the flow check (Duct condition test) : FLOW CHECK (DUCT CONDITION TEST)

Your dryer features FlowSenseTM , an innovative sensing system that automatically detects blockages and restrictions in dryer ductwork. Keeping ductwork clean of lint buildup and free of restrictions allows clothes to dry faster and reduces energy use.

NOTE: When the dryer is first installed, this test should be performed to alert you to any existing problems with the exhaust duct in your home. However, since the test performed during normal operation provides more accurate information on the condition of the exhaust duct than does the installation test, the number of bars displayed during the two tests may not be the same.

To activate the flow check (Duct condition test) :

NOTE: Dryer heating test must be performed before proceeding. Then perform the duct condition test below:

1Press and hold the DAMP DRY BEEP and TEMP. CONTROL buttons at the same time. While holding these buttons, press POWER ON/OFF.

2The dryer will show lnS in the number display to indicate that it is in duct condition testing mode.

3Press START/PAUSE. The dryer Manual background will run for approximately 2

minutes to test for blockages or restrictions to air fl ow in the ductwork.

Manual background If “YES” is shown in the display,

the ductwork is free from blockages or restrictions.

Manual background If “no” is shown in the display, the

dryer ductwork has a blockage

that needs to be removed

immediately.

IMPORTANT: Do NOT interrrupt the test cycle!

Correct Venting

Restricted or Blocked Airflow

Avoid long runs or runs with multiple elbows or bends.

Check for blockages and lint buildup.

Make sure the ductwork is not crushed or restricted.

Manual background 24

Page 24
Image 24
LG Electronics P154 manual Flow Check Duct Condition Test, To activate the flow check Duct condition test