 Three-Wire Connection for Electric Dryers: Power Cord

CONNECTING ELECTRIC DRYERS (cont.)

USA ONLY

wWARNING:

Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Manual background Three-Wire Connection for Electric Dryers: Power Cord

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

Terminal

Manual background Block

UL-Listed

Manual background Strain Relief

UL-Listed 3-Wire Manual background Power Cord

Use a 30-amp, 240V, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

Hot

Neutral

Hot

(Black)

(White)

(Red)

Ground Screw Manual backgroundManual backgroundManual background

Ground Wire

1Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30A, 240V, 3-wire, #10 AWG-minimum copper conductor power cord through the strain relief.

2Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten all screws securely. Reinstall the terminal block access cover.