ExternalControlDeviceSetup
Use this function to specify a monitor ID number.
Refer to 'Real Data Mapping 1'. See page 37.
1. Press the MENU button and then use D /E button to select the SPECIAl, menu.
2. Press theG button and then use D/E button to select Set ID.
3. Press the G button and then use F /(5 button to adjust Set ID to choose the
desired monitor IDnumber. The adjustment range ofSet ID is 1 ~ 99.
4. Press the ENTER button to save.
• Baud rate :9600 bps (UART)
• Data length : 8 bits
• Parity :None
* Use a crossed (reverse) cable.
• Stop bit: 1 bit
• Communication code :ASCII code
COMMAND 1 COMMAND 2 DATA
(Hexadecimal)
01. Power k a 0~ 1
02. Input Select k b 0~ 6
03.Aspect Ratio k c 0~ 3
04. Screen Mute k d 0~ 1
05. Volume Mute k e 0~ 1
06. Volume Control k f 0 ~ 64
07. Contrast k g 0~ 64
08. Brightness k h 0~ 64
09. Color k i 0 ~ 64
10.Tint k i 0 ~ 64
11.Sharpness k k 0 ~ 64
12.OSD Select k I 0 ~ 1
13.Remote ControlLock Mode k m 0~ 1
14. PIP/DW k n 0 ~ 3
15.Split Zoom k p 0 ~99
16. PIP Position k q 0 ~ 3
17.Treble k r 0~ 64
18. Bass k s 0 ~ 64
19. Balance k t 0 ~ 64
20. Color Temperature k u 0 ~ 3
21. Red Adjustment k v 0~ 3C
22. Green Adjustment k w 0 ~ 3C
23. Blue Adjustment k $ 0 ~ 3C
24. PIP Input Source k y 0 ~ 6
25.Abnormal State k z 0 ~ a
26. ISM Method i p 0~ 3
27. Low Power j q 0~ 1
28. Orbiter Time Setting j r 1 ~ FE
29. Orbiter Pixel Setting j s 1~9
30. Picture Size j t 0~14
31.Auto Config j u 1
COM- COM- DATA0 DATA1 DATA2 DATA3
MAND1 MAND2 (Hexadecimal)(Hexadecimal)(Hexadecimal)(Hexadecimal)
32.Tune Command m a 01 ~ 7D 0 0 mainsub/Tunet3and
33. Channel Add/Del m b 0 ~ 1
34. Key m c Key code
Transmission
[C_ommand2][ ][Set ID][ ][Data][Cr]
* [Command 1]: First command to control PDP set. (j, k or m)
* [Command 2]: Second command to control PDP set.
* [Set ID]: You can adjust the set ID to choose desired monitor
ID number in Special menu. Adjustment range is 1
~ 99. When selecting Set ID 'O', every connected
PDP set is controlled. Set IDis indicated as deci-
mal (1~99) on menu and as Hexa decimal
(0xO~0x63) on transmission/receiving protocol.
* [DATA]: To transmit command data.
Transmit 'FF' data to read status of command.
* [Cr]: Carriage Return
ASCII code '0xOD'
* [ ]: ASCII code 'space (0x20)'
OK Acknowledgement
[[Command2][ ][Set ID][ ][OK][Data][x] [
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
[[Command2][ ][Set ID][ ][NG][Data][x] [
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving abnormal data from non-viable
functions or communication errors.
Data l:lllegalCode
2: Not supported function
3: Wait more time
Owner's Manual 37