DRAIN MALFUNCTIONING
■
Is the drain hose twisted or frozen?
NO
Is the impeller of the drain pump clogged?
NO
Is the connector disconnected, disassembled?
NO
Is the coil of drain pump
YES
YES
YES
YES
Repair drain hose.
Remove foreign material.
Reconnect or repair the connector.
Replace the pump assembly.
(6) |
(5) |
2 |
1 |
PWB ASSEMBLY (MAIN)
NO
When checking voltage between connectors
( , ) on spinning, is the voltage 220 - 240V~ NO as the figure?
Replace the PWB assembly (Main).
■
Is the drain hose kinked or frozen?
NO
Is the filter of drain pump clogged?
NO
YES
YES
Repair drain hose.
Remove foreign material.
2 | 1 |
Is the connector disconnected or is the contact bad?
NO
Is the coil of drain pump
NO
YES
YES
Reconnect or repair the connector.
Replace the pump assembly.
|
|
|
|
|
|
|
|
| When checking voltage between two | |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| receptacles as shown ( , ) on spinning, | |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| is the voltage | |
|
|
|
|
|
|
|
|
| ||
PWB ASSEMBLY (MAIN) | ||||||||||
|
NO
Replace the PWB assembly (Main) .
34