8. TROUBLESHOOTING

8-1.BEFORE PERFORMING SERVICE

Be careful of electric shock or disconnecting the parts while troubleshooting.

Voltage of each terminal in AC 220-240V and DC while applying an electric current.

8-2.QC TEST MODE.

Pressing RINSE ( ), and SPIN ( ) button simultaneously.

Power supply ON with pressing upper two button. then buzzer sound twice.

Press the START/PAUSE (

 

 

 

 

 

 

) button as follows.

 

 

 

 

Press the START/PAUSE (

 

 

 

 

 

 

) button more 4 times until stop spinning

 

 

 

 

 

WD-1223(5)F(H)(B) / WD-1243(5)F(H)(B) / WD-102(4)1(5)W(F)(H) WD-102(4)1(5)F(H)B / WD-1041(3)F(H)B

Pressing number of

Checking Point

Display Status

START/PAUSE

button

 

 

None

 

 

All lamps turn on

 

 

 

 

 

 

1 time

 

 

Clockwise spin (right)

Motor rpm (About 45)

 

 

 

 

 

2 times

 

 

Low speed spin

Motor rpm (About 63~67)

 

 

 

 

 

3 times

 

 

High speed spin

Motor rpm (About 114~117)

 

 

 

 

 

4 times

 

 

Inlet valve for pre-wash operation

Water level frequency (25~65)

 

 

 

 

 

5 times

 

 

Inlet valve for main-wash operation

Water level frequency (25~65)

 

 

 

 

 

Hot inlet valve in case of hot water fill

 

 

 

 

 

 

 

 

 

6 times

 

 

Inlet valve for main-wash operation

Water level frequency (25~65)

 

 

 

 

 

7 times

 

 

Counterclockwise spin (left)

Motor rpm (About 45)

 

 

 

 

 

8 times

 

 

A Heater is in operation for 3 sec.

Water Temperature

 

 

 

 

 

9 times

 

 

Draining pump operation

Water level frequency

 

 

 

 

 

10 times

 

 

Auto off operation

 

 

 

 

 

 

20

Page 21
Image 21
LG Electronics WD-1042F(H)(B), WD-1042FH Troubleshooting, Before Performing Service, QC Test Mode, Start/Pause