HEATING CONTINUOUSLY ABOVE

THE SETTING WATER TEMPERATURE

WD-1223(5)F(H)(B)/WD-1243(5)F(H)(B) / WD-1041(3)F(H)B / WD-102(4)1(5)F(H)B / WD-803(4)0F(H)B

(1)

When disconnect the connector(1) on the

 

PWB assembly (Main) is the resistance of the

 

natural connectors

( Blue/White, Violet),

 

(Blue, White)

between 2.5k to 180k

 

(105 ~0 )?

2

1

 

 

4

3

YES

When checking thermistor on the tub cover, is the thermistor loosened above 2mm from the rubber?

NO

YES

Replace the thermistor. (6322FR2046B)

Press the thermistor tightly to the rubber.

WD-803(4)0(W)(F)(H)/WD-102(4)1(5)W(F)(H)/WD-1042F(H)

1

Is the resistance between two receptacles with

 

BL/WH wires parted from PWB assembly

NO

2.5k

to 180k (105 ~0 )?

 

YES

When checking thermistor on the tub cover,

is the thermistor gotten more than 2 mm out of the

YES

 

rubber?

 

Replace the thermistor. (6322FR2046B)

Get the thermistor back to the rubber.