Putting into operation

Putting into operation

(3)Temperature display

3.2 Temperature display

The following are displayed in normal operation:

-the set cooling temperature

4 Putting into operation

4.1 Transporting the appliance

CAUTION

Risk of injury and danger of damage as a result of incorrect transport!

u Transport the appliance in a packed condition. u Transport the appliance upright.

u Do not transport the appliance without assistance.

4.2 Installing the appliance

WARNING

Fire hazard due to dampness!

If live parts or the mains lead become damp this may cause short circuits.

u The appliance is designed for use in enclosed areas. Do not operate the appliance outdoors or in areas where it is exposed to splash water or damp conditions.

WARNING

Risk of fire due to short circuit!

If the mains cable/connector of the appliance or of another appliance touch the rear of the appliance, the mains cable/ connector may be damaged by the appliance vibrations, leading to a short circuit.

u Stand the appliance so that it is not touched by connectors or main cables.

u Do not plug the appliance or any others into sockets located near the rear of the appliance.

WARNING

Fire hazard due to refrigerant!

The refrigerant R 600a is environmentally friendly but flam- mable. Escaping refrigerant may ignite.

u Do not damage the piping of the refrigeration circuit.

WARNING

Fire hazard and danger of damage!

u Do not place appliances emitting heat e.g. microwaves, toasters etc. on the appliance!

WARNING

Blocked ventilation openings pose a risk of fire and damage! u Always keep the ventilation openings clear. Always ensure

that the appliance is properly ventilated!

NOTICE

Risk of damage due to condensate!

If your appliance is not a Side-by-Side (SBS) appliance:

u do not install the appliance directly alongside a further refrig- erator/freezer.

q In the event that the appliance is damaged, contact the supplier immediately before connecting to the mains.

q The floor at the site must be flat and level.

q Do not install the appliance in a location where it is exposed to direct radiation of the sun, next to a cooker, heater and similar.

q Always stand the appliance backed directly to the wall using the enclosed wall spacers (see below).

q The appliance may be moved only when it is empty. q Do not install the appliance without assistance.

q The more R 600a refrigerant there is in the appliance, the larger the room in which the appliance is standing needs to be. In rooms that are too small, a flammable mix of gas and air may be created if there is a leak. According to the EN 378 standard, every 11 g of R 600a refrigerant requires at least 1 m3 space in the room for the appliance. The amount of refrigerant in your appliance is on the type plate inside the appliance.

u Detach the connecting cable from the rear of the appliance, removing the cable holder at the same time because other- wise there will be vibratory noise!

u Remove the protective film from the outside of the appli- ance.*

NOTICE*

The stainless steel doors are provided with a high-quality surface coating and must not be treated using the accompa- nying care product.

Otherwise the surface coating will be affected.

u Wipe the coated door surfaces using a soft, clean cloth only.

u Apply a stainless steel cleaner only to the stainless steel side walls evenly, wiping with the grain. Subsequent cleaning becomes easier as a result.

u Wipe side walls with a paint finish using a soft, clean cloth only.

uRemove the protective film from the decorative trims.*

uRemove all transit supports.

The spacers supplied with some appliances must be used to achieve the stated energy consumption. These will extend the depth of the appliance by approx. 35 mm. The appliance is fully functional if the spacers are not used, but does have a slightly higher energy consumption.

u In the case of an appliance with enclosed wall spacers, mount the wall spacers on the back of the appliance at the top left and right.

uDispose of packaging material (see 4.5) .

* Depending on model and options