ICEMAKER

ICEMAKER

Water Connection - Figure 22

Please read the first three points of the safety instructions and warnings before connecting the appliance to the main water supply.

The water pressure must be between 21.8-87.0 psi (1.5-6 bar).

Use a 1/4" OD copper line to connect the water supply to the solenoid valve. This is not supplied with the refrigerator (Figure 22).

A shut-off valve, such as the saddle valve illustration here, must be installed between the hose line and the main water supply so the water supply can be stopped if necessary.

Do not install the shut-off valve behind the refrigeration unit.

Figure 22

If you have hard water, we recommend you install a water softener. Also, a filter must be installed if the water contains solids such as sand.

All equipment and devices used to supply the water to the appliance must comply with the current regulations for your geographical area.