INSTALLATION GUIDELINES

INSTALLATION GUIDELINES

Area Requirements

Verify the following:

Floors can support refrigerator’s weight plus approximately 1200 pounds (544 kg) of food weight.

Finish kitchen floor height is level. Kitchen cabinet that the appliance is installed in must be shimmed to the floor level if the floor heights are not equal.

Remove anything attached to the rear or side walls of appliance that would prevent proper installation or impede proper ventillation.

Cutout dimensions are accurate.

Electrical outlet is in correct location.

Do not install this refrigerator-freezer next to any other refrigerator or freezer except another Liebherr model. Liebherr models are designed to allow side-by-side installation. They are equipped with

a heating system to eliminate condensation when refrigerators or freezers are installed side-by-side. Installing this refrigerator-freezer next to any other refrigerator or freezer can cause condensation or cause damage to the Liebherr refrigerator-freezer.

Electrical Requirement

If codes require a separate grounding circuit to be used, have a qualified electrician install the circuit.

!WARNING

ELECTRICAL SHOCK HAZARD!

Do not ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. Do not have a fuse in the neutral or grounding circuit.

Failure to follow these instructions could result in death or serious injury.

!WARNING

ELECTRICAL SHOCK HAZARD!

Electrically ground refrigerator.

Do not use an extension cord.

Failure to follow these instructions could result in fire, death or serious injury.

!WARNING

ELECTROCUTION HAZARD!

Electrical Grounding Required. This appliance is equipped with a three-prong (grounding) polarized plug for your protection against possible shock hazards.

DO NOT remove the round grounding prong from the plug.

DO NOT use a two-prong grounding adapter.

DO NOT use an extension cord to connect power to the unit.

Failure to follow these instructions could

result in death or serious injury.

Customer’s Responsibility

A 115 Volt, 60 Hz, 15 Amp fused electrical supply is required. We recommend using a dedicated circuit for this appliance to prevent electrical overload. Follow the National Electrical Code and local codes and ordinances when installing the receptacle.

Venting the Appliance

DO NOT restrict the air flow. Air flow must be provided for the appliance to operate. The factory air vents provide 31 square inches (200 cm2) of air flow per appliance. If you are replacing the factory air vents with an overlay, the air flow must be the same or greater than the factory air vents.