Liebherr HCS 20 installation instructions Connection to the Water Supply, Icemaker

Models: HCS 20

1 14
Download 14 pages 6.19 Kb
Page 9
Image 9
Connection to the Water Supply

ICEMAKER

Connection to the Water Supply

1.Install the shut-off valve, water filter and auto- matic shut-off device as required.

2.The solenoid valve has a Metric R3/4 male con- nector. A R3/4 (metric) to a 1/4" OD adapter is supplied with the icemaker.

3.Move the appliance towards the final position and leave a gap of approx. 30" behind.

4.Insert the water supply line into its intended opening at the back of the appliance (Figure 11).

5.Move the power supply line to the area of the electrical outlet.

Do not connect to the electrical outlet before the installation is completed and the water line is connected to the solenoid valve.

6.Push the appliance slowly to the back wall until the compressor mounting plate makes contact with the anti-tipping bracket (Figure 12).

To prevent the appliance from tipping forward the compressor mounting plate must have contact with the anti tipping bracket (Figure 12).

7.The water line is visible at the front of the appli- ance. Screw the OD adapter onto the solenoid valve and connect the water line with the adapt- er (Figure 13).

8.Open the shut-off valve for the water supply and check the entire water system for leaks.

Figure 11

Manual background Wall

Appliance

Anti - tipping bracket

Manual backgroundManual backgroundManual background Compressor mounting Manual backgroundManual backgroundManual background plate

Figure 12

Figure 13

9