Setting up

Appliance dimensions

• Avoid positioning the appliance in direct sunlight or near cookers, radiators and similar sources of heat.

• The floor on which the appliance stands should be horizontal and level.

• The ventilation grilles should not be obstructed. Always ensure that there is good ventilation and that the outward flowing air is able to escape.

• Standard EN 378 specifies that the room in which you install your appliance must have a volume of 1 m³ per 8 g of R 600a refrigerant used in the appliance, so as to avoid the formation of inflammable gas/air mixtures in the room where the appliance is located in the event of a leak in the refrigerant circuit. The quantity of refrigerant used in your appliance is indicated on the type plate on the inside of the appliance.

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type plate. The position of the type plate is shown in the description of the appliance.

The socket must be properly earthed and protected by a fuse. The tripping current of the fuse must be between 10 A and 16 A. The socket must not be situated behind the appliance and must be easily accessible.

Do not connect the appliance using an exten- sion cable or extension socket.

Appliance venting

The required air flow is directed through the plinth.

It is important to use the provided ventilation grille for the ventila- tion opening.

This opening must not be covered.

A = 76 mm B = 2027 mm C = 910 mm D = 76 mm E = 910 mm G = 1078 mm H = 943 mm