GB

3. Insert the bent section of the hose through the opening at the rear of the appliance.

4. Connect the hose to the solenoid valve at the front side of the appliance.

5.Route the mains cable towards the socket.

6.Route the water hose towards the water shut-off valve.

WARNING!

Do not connect the appliance to the power supply until the installation is completed.

CAUTION!

Lay the mains cable and the water hose in such a way that they will not be damaged when the appliance is slid into the installation recess.

7.Push the appliance slowly into the recess until the compressor mounting plate touches the anti-tipping bracket.

WARNING!

To prevent the appliance from tipping forwards, the compres- sor mounting plate must be touching the anti-tipping bracket!

Wall

Appliance

Anti-tipping bracket

Compressor mounting plate

8.Connect the hose to the shut-off tap.

Open the shut-off tap and check the system for leakage.

Important!

After the ice maker has been switched on, the water supply system must be bled. See the section Bleeding the ice maker in the operating instructions.

5.6.

15

Page 5
Image 5
Liebherr liebherr manual